The Pramac GA series of LPG and Natural Gas generators, the Pramac GA10000 is reliability economical thanks to the robust Generac G-Force engine. The Overhead Valve (OHV) engine produces 10kVA / 10 KW of power effortlessly and has been designed for residential backup use. Its best for powering the home where the use of small to medium appliances, heating, lights, and such is required. Plus, it can power sensitive electrical equipment too, Its compact size and low sound levels makes it a market leader in LPG and Natural Gas Generators.

MPN: GA10000
Our Price: £4,155.54 excl VAT
Our Price: £4,986.65 inc VAT
Please contact us for delivery information

Delivery of this item usually takes two to three working days. Smaller items that are in stock, ordered before 12pm are usually dispatched the same day. Please contact us if needed sooner. For larger items please contact us to confirm stock levels.

Pramac GA10000 10Kw LPG & Natural Gas Back-up Generator Single-Phase

The Pramac GA series of LPG and Natural Gas generators, the Pramac GA10000 is reliability economical thanks to the robust Generac G-Force engine. The Overhead Valve (OHV) engine produces 10kVA / 10 KW of power effortlessly and has been designed for residential backup use. Its best for powering the home where the use of small to medium appliances, heating, lights, and such is required. Plus, it can power sensitive electrical equipment too, Its compact size and low sound levels makes it a market leader in LPG and Natural Gas Generators.

Main Features

  • GENERAC G-FORCE OHV Engine
  • Natural Gas or LP Gas Operation
  • Electronic Governor
  • Sound Attenuated Aluminium Enclosure
  • True Power™ Electrical Technology
  • Two Line LCD Multilingual Digital Evolution™ Controller
  • System Status & Maintenance Interval LED Indicators
  • Flexible Fuel Line Connector
  • Wi-Fi communications standard
  • Free Mobile Link™ Wi-Fi Remote Monitoring through App
  • 5-Year Limited Warranty
  • Compatible with Transfer Switch for ease of use.

Performance

  • Stand By Power [ESP] (Liquid Propane) VA 10000
  • Stand By Power [ESP] (Natural Gas) VA 10000
  • Frequency Hz 50
  • Voltage V 230 Single phase
  • Phase 1
  • Power factor cos ϕ 1

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating.(All ratings in accordance with BS5514, ISO3046, and DIN6271). Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power, condition, etc. Maximum power decreases about 3.5 percent for every 305 meters above sea level; and also will decrease about 1 percent for each 6 °C above 16 °C.

Engine Specification

  • Engine Brand Generac
  • Model G-FORCE
  • 1000 SERIES
  • Type OHV
  • Engine cooling system Air
  • Nr. of cylinder and disposition 2 V angle
  • Displacement cm³ 999
  • Compression Ratio 9.5:1
  • Starting system Electric
  • Electric circuit V 12
  • Speed governor Electronic
  • Operating Speed-Nominal rpm 3000
  • Oil capacity l 1.8
  • Fuel Natural Gas or LP Gas
  • Natural Gas: Fuel consumption 50% m³/h 3.51
  • Natural Gas: Fuel consumption 100% m³/h 5.30
  • Liquid Propane Gas: Fuel consumption 50% l/h 4.79
  • Liquid Propane Gas: Fuel consumption 100% l/h 7.62

Note: Fuel pipe must be sized for a full load. Required fuel pressure to generator fuel inlet at all load ranges 1.74-3.24 kPA (3.5-7" water column) for natural gas, 4.73-5.48 kPA (10-12" water column) for LP gas. Outputs are based upon values @ 1000 Btu per cubic feet with NG and 2500 Btu per cubic feet with LPG @ 37.26 Megajoules per cubic meter with NG and 93.15 Megajoules per cubic meter with LPG.

Alternator Specification

  • Frequency Hz 50
  • Voltage regulation system AVR
  • Single Phase (1)
  • Poles 2

Data Current

  • Max current (Liquid Propane) A 43.48
  • Max current (Natural Gas) A 43.48
  • Circuit breaker A 40

Unit Size

  • Length (L) mm 1232
  • Width (W) mm 648
  • Height (H) mm 733
  • Dry weight kg 176

Noise Level

  • Guaranteed noise level (LWA) dB(A) 95
  • Noise pressure level @ 7 m dB(A) 63
  • Quiet-Test Mode dB(A) 54

Features & Benefits

  • Generac G- Force design: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption resulting in longer engine life.
  • “Spiny-lok” cast iron cylinder walls: Rigid construction and added durability provide long engine life.
  • Electronic ignition/spark advance: These features combine to assure smooth, quick starting every time.
  • Full pressure lubrication system: Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200-hour oil change interval.
  • Low oil pressure shutdown system: Shutdown protection prevents catastrophic engine damage due to low oil.
  • High-temperature shutdown: Prevents damage due to overheating.
  • Generator
  • Revolving field: This allows for a smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator.
  • Skewed stator: Produces a smooth output waveform for compatibility with electronic equipment.
  • Displaced phase excitation: Maximizes motor starting capability.
  • Automatic voltage regulation: Regulates the output voltage to ±1% prevents damaging voltage spikes.
  • True Power Technology: Less than 5% total harmonic distortion (THD).

Evolution Controls

  • Auto/Manual/Off illuminated buttons: Selects the operating mode and provides easy,
  • at-a-glance status indication in any condition.
  • Sealed, raised buttons: Smooth, weather-resistant user interface for programming and
  • operations.
  • Utility voltage sensing: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
  • Utility interrupt delay: Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer.
  • Engine warm-up: Ensures engine is ready to assume the load, setpoint approximatelyn 5 seconds.
  • Engine cool-down: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
  • Programmable seven-day exercise: Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for a weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner.
  • Smart battery charger: Delivers charge to the battery only when needed at varying
  • rates depending on outdoor air temperature. Compatible with lead-acid and AGM-style batteries.
  • the Main line circuit breaker: Protects the generator from overload.
  • Electronic governor: Maintains constant 50 Hz frequency.
  • Wi-Fi Connectivity

Unit

  • Weather protective Aluminum Enclosure: Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 240km/h.b Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.
  • Electrostatically applied textured epoxy paint for added durability.
  • Enclosed muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
  • Small, compact, attractive: Makes for an easy, eye appealing installation.

Control

Evolution™ Digital Controller

Precise control of all generator systems ensures clean and stable electrical output.

Backlit LCD screen with automatically adjusting contrast for easy viewing in changing conditions.

Mode Buttons:

  • Auto/Manual/Off
  • Program Functions and Protections:
  • Ready to Run/Maintenance Messages
  • Engine Run Hours Indication
  • Programmable start delay
  • Utility Voltage Loss/Return to Utility Adjustable
  • Future Set Capable Exerciser/Exercise Set Error Warning
  • Run/Alarm/Maintenance Logs (50 Events Each)
  • Engine Start Sequence (cyclic cranking: 16 sec on, 7 rest, 90 sec maximum duration).
  • Smart Battery Charger
  • Charger Fault/Missing AC Warning
  • Low Battery/Battery Problem Protection and Battery Condition Indication
  • Automatic Voltage Regulation with Over and Under Voltage Protection
  • Under-Frequency/Overload/Stepper Overcurrent Protection
  • Safety Fused/Fuse Problem Protection
  • Automatic Low Oil Pressure/High Oil Temperature Shutdown
  • Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown
  • High Engine Temperature Shutdown
  • Internal Fault/Incorrect Wiring Protection
  • Common External Fault Capability
  • Field Upgradeable Firmware
  • Wi-Fi MOBILE LINK™
  • Circuit Breaker
  • AUTOMATIC BACKUP POWER GENERATORS
  • Compatible with LTS Load Transfer Switches (Accessory)

LTS Load Transfer Switch

The Load Transfer Switch (LTS) panel operates the power supply changeover between the generator and the Mains in backup applications, guarantying the feeding to the load within a short period of time. It consists of a standalone cabinet that can be installed separately from the generating set. The logic control of the power supply changeover is operated by means of the Automatic Control panel mounted on the generating set, so therefore none logic device is required on the LTS panel.