Delivery Info

Pramac GSW180P 180kVA / 144kW 3-Phase Perkins Engine Diesel Generator

Pramac GSW180P 180kVA / 144kW 3-Phase Perkins Engine Diesel Generator

Pramac GSW180P is a 180kVA / 144kW 3-phase diesel generator with a Perkins engine. Built with both quality and performance in mind, a 1500rpm diesel unit benefits of longer lifespan and is suitable for many applications.

MPN: GSW180P IIIA
Call Us For Prices
Contact us for up to date pricing and delivery options.

Pramac GSW180P 180kVA / 144kW 3-Phase Perkins Engine Diesel Generator

PrPramac GSW180P is a 180kVA / 144kW 3-phase diesel generator with a Perkins engine. Built with both quality and performance in mind, a 1500rpm diesel unit benefits of longer lifespan and is suitable for many applications.

Main Features

  • Frequency Hz 50
  • Voltage V 400
  • Power factor cos ϕ 0.8
  • Phase 3

Power Rating

  • Emergency Standby Power ESP kVA 180.18
  • Emergency Standby Power ESP kW 144.14
  • Prime power PRP kVA 163.20
  • Prime power PRP kW 130.56

ESP - Emergency Standby Power

It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power
output over 24 h of operation shall not exceed 70 % of the ESP.

PRP - Prime Power:

It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not
exceed 70 % of the prime power.

Engine Specification

  • Engine Brand Perkins
  • Model 1106D
  • E70TAG3
  • [50Hz] Exhaust emission level Stage IIIA
  • Engine cooling system Water
  • Nr. of cylinder and disposition 6 inline
  • Displacement cm³ 7010
  • Aspiration Turbocharged
  • Speed governor Electronic
  • Prime gross power PRP kW 148.1
  • Maximum gross power LTP ESP kW 162.8
  • Oil capacity l 17.5
  • Lube oil consumption PRP (max) % 0.1
  • Coolant capacity l 21
  • Fuel Diesel
  • Specific fuel consumption 75% PRP g/kWh 231.7
  • Specific fuel consumption PRP g/kWh 212.1
  • Starting system Electric
  • Starting engine capability kW 4
  • Electric circuit V 12

Alternator Specification

  • Alternator Mecc Alte
  • Model ECO38-1S
  • Voltage V 400
  • Frequency Hz 50
  • Power factor cos ϕ 0.8
  • Type Brushless
  • Poles 4
  • Standard AVR DSR
  • Voltage tolerance % 1
  • Efficiency @ 75% load % 92.6
  • Class H
  • IP protection 23

Canopy

• Soundproof canopy made up of modular panels, realized with zinced steel as

treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a fully weatherproof enclosure.

  • • Easy access to the genset for maintenance purposes thanks to Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles and internal perforated galvanized steel-sheet; Detachable panels, with screws holes protected by a rubber tap.
  • • Control panel protection door provided with suitable window and lockable handle.
  • • Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid.
  • • Single detachable lifting eye placed on the roof.

Soundproof

  • • Noise attenuation thanks to soundproofing material
  • • Efficient residential silencer placed inside the canopy

Dimensional Data

  • Length (L) mm 3414
  • Width (W) mm 1338
  • Height (H) mm 1768
  • Dry weight kg 2050
  • Fuel tank capacity l 350
  • Fuel tank material Plastic

Autonomy

  • Fuel consumption @ 75% PRP l/h 31.04
  • Fuel consumption @ 100% PRP l/h 37.39
  • Running time 75% PRP h 11.28
  • Running time 100% PRP h 9.36

Noise Level

  • Guaranteed noise level (LWA) dB(A) 97
  • Noise pressure level @ 7m 68

Specification